Rinnai Mc 91q 2a User Manual
This manual provides service information for the models below. This table cross references each model to the applicable page number for internal component replacement instructions. Condensing Tankless Water Heater Service Manual. KA Condensing. KB Condensing. Created Date: 3/13/2009 3:36:15 PM. RV53i & RV53e Operation and Installation Manual 3 Specifications Rinnai is continually updating and improving products. Therefore, specifications are subject to change without prior notice. The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value listed is for the purpose of input adjustment. This manual provides service information for the models below. This table cross references each model to the applicable page number for internal component replacement instructions. Condensing Tankless Water Heater Service Manual. KA Condensing. KB Condensing.
- Rinnai Mc-91q-2a Manual
- Rinnai Mc 91q 2a User Manual Download
- Rinnai Mc 91q 2a User Manual Online
- Rinnai Mc 91q 2a User Manual Pdf
Endless options, The rinnai luxury series tankless water heaters, Energy-efficient hot water never looked so good
HYDRONIC
FURNACES
DIRECT VENT
WALL FURNACES
THE RINNAI LUXURY SERIES
TANKLESS WATER HEATERS
ENERGY-EFFICIENT HOT WATER NEVER LOOKED SO GOOD
WHOLE-HOUSE ANd COMMERCIAL TANkLESS WATER HEATING SOLUTIONS
R-CNWH-E-12r10 © 2011 Rinnai America Corporation 5M 04/2011
FOR MORE INFORMATION ON RINNAI pROdUCTS
OTHER RINNAI LITERATURE AvAILABLE
Rinnai America Corporation
103 International Drive
Peachtree City, GA 30269
Rinnai Mc-91q-2a Manual
Toll Free 1-800-621-9419
Phone: 678-829-1700 • Fax: 678-364-8643
Visit our Website www.rinnai.us
E-mail: marketing@rinnai.us
RINNAI
GREEN ADVANTAGES
MC-100V-1-S
Deluxe Digital
Controller
BC-100V-1US-S Bath-Fill
Digital Controller
MC-91-1-S Digital
Controller Integrated in
Internal Unit; Standard
Digital Controller for
Exterior Unit
More Than 30 Million Installations Worldwide Make Rinnai #1!
At Rinnai, we’ve sold more tankless water heaters worldwide than anyone else. Our complete
commitment to safety, quality, support and the environment has also made us #1 in the U.S. market.
Tomorrow’s Innovation Today
As the leading manufacturer of gas heating products worldwide, Rinnai continues innovating
to ensure a greener environment. Rinnai’s superior heating and hot water technologies deliver
greater effi ciency and reliability, so everyone benefi ts – with environmental preservation and
energy conservation that results in a better planet for us all.
INTERIOR ROOF OR WALL VENTING
The Rinnai can be vented vertically or horizontally.
CUSTOM INSTALLATIONS to blend
in with the interior (shown at left with
optional pipe cover) or to be recessed on
an exterior wall of the home.
EXTERIOR WALL-MOUNT
installations require no
additional venting accessories.
This sewing machine is designed and manufactured for household use only. Read all instruction before using this sewing machine. DANGER – To reduce the risk of electric shock: 1. An appliance should never be left unattended when plugged in. Always unplug this sewing machine from the electric outlet immediately after using and before cleaning. Usha janome flair sewing machine manual. Instruction Manual. IMPORTANT SAFETY INSTRUCTIONS This sewing machine is not a toy. Do not allow children to play with this machine. The machine is not intended for use by children or mentally infirm persons without supervision. This sewing machine is designed and manufactured for household use only.
Accessories
Rinnai’s line of digital controllers allows you to set water
temperature precisely for multiple locations in your home, analyze
and troubleshoot the water heater, and even automatically fi ll
your bath to a pre-set temperature and volume. (Note: the MC-91
controller is integrated on the front panel of the RL Series interior
units and comes standard with all RL Series exterior units.)
Flexible Installation
For interior installation, Rinnai units use a concentric venting
system – a single vent assembly featuring an inner, metal
vent for exhaust gases and an outer PVC or metal tube
for bringing combustion air from outdoors. The result: a
direct-vent, sealed-combustion system that offers optimum
safety, performance and ease of installation.
Exterior units can be installed in a recessed enclosure, which can be
painted or textured to match your home’s panel or brick siding.
Multiple Units
If you need more than one unit for your larger home, spa or
body spray shower, Rinnai’s EZConnect
®
feature allows you to
link two units with a simple cord. For even larger applications,
your installer can place up to 25 units in parallel.
Other benefi ts include:
• Integrated Condensate
Collector: ensures
condensation doesn’t drain
back into unit, and reduces
cost of venting.
• High-Altitude Operation: all
RL Series units can be adjusted
for use up to 10,200 ft.
Rinnai is continually updating and improving products; therefore, specifi cations are subject to change without
prior notice. Local, state, provincial and federal codes must be adhered to prior to and upon installation.
0
1
2
3
4
5
6
7
8
9
1 0
Tankless Water Heater - Maximum Flow Curves
0
25
50
75
100
125
Temperature Rise (
˚
F)
Ho
t W
ate
r F
low
Ra
te
(gp
m)
150
RL94i/e (NG)
RL94i (LP)
RL75i/e
** Units come with a default maximum temperature of 120° F for increased safety and code compliance. An option to increase
the max temp to 140° F is also available.
*** To achieve temperatures over 140° F, an MCC-91 commercial controller must be purchased separately.
† 0.4 GPM activation rate for RL Series
fl exibility + control
HOT WATER FLOW CHART
MODEL NO.
RL94i/e
RL75i/e
TEMP. RISE (°F)
GPM
GPM
140
2.4
2.1
135
2.5
2.2
130
2.6
2.3
125
2.7
2.4
120
2.8
2.5
115
2.9
2.6
110
3.0
2.7
105
3.2
2.9
100
3.3
3.0
95
3.5
3.2
90
3.7
3.3
85
3.9
3.5
80
4.2
3.8
75
4.4
4.0
70
4.7
4.3
65
5.1
4.6
User manual for omron blood pressure monitor bp760 7 series. 60
5.5
5.0
55
6.0
5.5
50
6.6
6.0
45
7.4
6.7
40
8.3
7.5
35
9.4
7.5
30
9.4
7.5
25
9.4
7.5
20
9.4
7.5
Interior Residential/Commercial Models
Models available in Natural Gas or Propane
RL75i
RL94i
Dimensions
14” W x 23” H x 10“ D
14” W x 23” H x 10“ D
Weight
51 lbs
53 lbs
Maximum/Minimum Gas Rate
(Input BTU’s)
180,000 /9,900 (NG)
180,000/10,300 (LP)
199,000/9,900 (NG)
190,000/10,300 (LP)
Hot Water Capacity Range
0.26 to 7.5 GPM
†
0.26 to 9.4 GPM
†
Energy Factor (NG and LP)
.82
.82
Thermal Effi ciency (NG and LP)
NA
NA
Temperature Range (Min - Max)
Residential**
Commercial***
98° F - 140° F
98° F - 160° F
98° F - 140° F
98° F - 185° F
Standard Digital Controller
MC-91-1
Optional Controller
MC-100V-1, BC100V-1, MCC-91-1
Exterior Residential/Commercial Models
Models available in Natural Gas or Propane
RL75e
RL94e
Dimensions
14” W x 23” H x 10“ D
14” W x 23” H x 10“ D
Weight
51 lbs
51 lbs
Maximum/Minimum Gas Rate
(Input BTU’s)
180,000 /9,900 (NG)
180,000/10,300 (LP)
199,000/9,900 (NG)
199,000/10,300 (LP)
Hot Water Capacity Range
0.26 to 7.5 GPM
†
0.26 to 9.4 GPM
†
Energy Factor (NG and LP)
.82
. 82
Thermal Effi ciency (NG and LP)
NA
NA
Temperature Range (Min - Max)
Residential**
Commercial***
98° F - 140° F
Rinnai Mc 91q 2a User Manual Download
98° F - 160° F
98° F - 140° F
98° F - 185° F
Standard Digital Controller
MC-91-1
Optional Controller
MC-100V-1, BC100V-1, MCC-91-1
endless options
Luxury Series Warranty
RL75i
Rinnai Mc 91q 2a User Manual Online
RL75e
RL94e
Warranty (some restrictions apply): Heat exchanger limited
warranty 12 years residential; 3 years when used in certain recirculating
systems; 10 years when used with a Rinnai hydronic furnace; 5 years
in commercial applications. All other parts: 5 years. *Labor: 5 years
residential and 2 years commercial for Luxury/Ultra models when
registered within 30 days of installation, 1 year all other applications.
For more warranty details, visit www.rinnai.us or call 1-800-621-9419.
R-CNWH-E-12r10_LSResidential_022811.indd 1-3
3/8/11 9:10:38 AM