Hp ML150 - ProLiant - G6 Pdf User Manuals. View online or download Hp ML150 - ProLiant - G6 User Manual, Installation Manual, Troubleshooting Manual. View and Download HP ProLiant ML150 quickspecs online. Generation 6. ProLiant ML150 Server pdf manual download. Also for: Proliant ml150 generation 6, Proliant ml150 g6.

  1. Hp Proliant Ml150 G6 Server Specification
  2. Hp Proliant Ml150 G6 Specs
  3. Hp Ml110 G6 Specs
  4. Hp Proliant Ml150 G6 Server User Manual 2016
  5. Hp Proliant Ml150 G6 Specs
Advertising

My name is Toby I'd like to start off this post with saying that i need the firmware to re-flash my BMC and maybe a guide or two, i cant seem to find any. HP ROM-Based Setup Utility User Guide Abstract This document details how to access and use the HP ROM-Based Setup Utility that is embedded in the system ROM of all HP ProLiant Generation 2 through 8 servers (except the HP ProLiant DL580 Gen8 server). All options and available responses are defined. HP ProLiant ML100 Series Server User Guide for HP ProLiant ML110 G2, G3, G4, and G5 Servers, ProLiant ML115 and ML115 G5 Servers, and ProLiant ML150 G2, G3, and G5 Servers Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems.

Software and configuration utilities 40

Remains available any time that the server is on

Displays on-screen tips for individual steps of a configuration procedure

Ml150

Beginning with ACU version 8.28.13.0, provides diagnostic functionality on the Diagnostics tab
(formerly known as Array Diagnostics Utility).

For optimum performance, the minimum display settings are 1024 × 768 resolution and 16-bit color. Servers
running Microsoft® operating systems require one of the following supported browsers:

Internet Explorer 6.0 or later

Mozilla Firefox 2.0 or later

For Linux servers, see the README.TXT file for additional browser and support information.
For more information about the controller and its features, see the HP Smart Array Controllers for HP ProLiant
Servers User Guide
on the HP website

(

http://bizsupport2.austin.hp.com/bc/docs/support/SupportManual/c01608507/c01608507.pdf

). To

configure arrays, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP
website Epson stylus photo r280 usb cable.

View and Download Samsung GALAXY S4 4G LTE user manual online. 4G LTE SMARTPHONE. GALAXY S4 4G LTE Cell Phone pdf manual download. Also for: Sgh-m919n, Galaxy s4. Manual for samsung galaxy s4.

(

http://bizsupport1.austin.hp.com/bc/docs/support/SupportManual/c00729544/c00729544.pdf

2016

).

Option ROM Configuration for Arrays

Before installing an operating system, you can use the ORCA utility to create the first logical drive, assign
RAID levels, and establish online spare configurations.
The utility also provides support for the following functions:

Reconfiguring one or more logical drives

Viewing the current logical drive configuration

Hp Proliant Ml150 G6 Server Specification

Deleting a logical drive configuration

Setting the controller to be the boot controller

Selecting the boot volume

If you do not use the utility, ORCA will default to the standard configuration.
For more information regarding the default configurations that ORCA uses, see the HP ROM-Based Setup
Utility User Guide
on the Documentation CD.
For more information about the controller and its features, see the HP Smart Array Controllers for HP ProLiant

Hp Proliant Ml150 G6 Specs

Servers User Guide on the HP website
(

http://bizsupport2.austin.hp.com/bc/docs/support/SupportManual/c01608507/c01608507.pdf

). To

configure arrays, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP
website
(

http://bizsupport1.austin.hp.com/bc/docs/support/SupportManual/c00729544/c00729544.pdf

).

HP Insight Diagnostics

The HP Insight Diagnostics utility displays information about the server hardware and tests the system to be
sure it is operating properly. The utility has online help and can be accessed using the Easy Set-up CD.

Hp Ml110 G6 Specs

Advertising

Hp Proliant Ml150 G6 Server User Manual 2016

This manual is related to the following products:
Popular Brands
Popular manuals
PrintRate this content

New model specific parts lists

IMPORTANT: To obtain current part number information for a specific product model, use the Standard Models page for this product family.

Click here to go to the Standard Models page for all model specific information and to access the product model parts lists .

  • The product Standard Models page now links the model SKU numbers to the spare parts list for each model found on the HP PartSurfer web site. (To report missing or incorrect parts information in PartSurfer, please use the 'Contact us' and 'Missing or incorrect data' links within the PartSurfer web site utility.)

  • To look up RoHS-compliant information in PartSurfer, use the component’s option part number or the sales order number for a system in which the component is used (available in the QuickSpecs or Standard Models page).

Mechanical components

Description
Customer Self Repair
Front bezel assembly - Louvered plastic bezel that covers the hard drive bays and has cut-outs for the removable media drives - Includes the removable media drive bay blanks, power button, lock, and key
Mandatory1
3
5U SAS/SATA large form-factor (LFF) non-hot-plug hard drive cage assembly - Does not include the backplane board
Mandatory1
Baffle
Mandatory1
Side panel
Mandatory1
  1. Mandatory1 - Parts for which customer self repair is mandatory. If user request HPE to replace these parts, user will be charged for the travel and labor costs of this service.

Electrical components

Description
Customer Self Repair
460 watt integrated AC power supply non-hot-plug - ATX style power supply with multiple outputs - Mounts in the upper rear corner of the server
Mandatory1
750 watt AC Common Slot (CS) 'Gold' hot-plug power supply - Does not support Power Discovery Services (black plug) - 92% efficiency, 100-240VAC at 50/60Hz - Mixing of power supplies in the same server is not supported, must be the same spare part number
2
519738-001
3
System I/O board (motherboard) - Supports select Intel Xeon 5500 (Nehalem) processors - Includes base pan assembly, alcohol pad, and thermal grease syringe - Processors must be the same spare part number
Optional2
2GB, 1333MHz, PC3-10600R-9, DDR3, dual-rank x8, 1.50V, registered dual in-line memory module (RDIMM)
Mandatory1
4GB, 1333MHz, PC3-10600R-9, DDR3, dual-rank x4, 1.50V, registered dual in-line memory module (RDIMM)
4GB, 1066MHz, PC3-8500R-7, DDR3, quad-rank x8, 1.50V, registered dual in-line memory module (RDIMM)
4GB, 1333MHz, PC3-10600E-9, DDR3, dual-rank x8, 1.50V, unbuffered with ECC dual in-line memory module (UDIMM)
1GB, 1333MHz, PC3-10600E-9, DDR3, single-rank x8, 1.50V, unbuffered with ECC dual in-line memory module (UDIMM)
2GB, 1333MHz, PC3-10600E-9, DDR3, dual-rank x8, 1.50V, unbuffered with ECC dual in-line memory module (UDIMM)
5
509505-001
6
Intel Xeon E5502 Dual-Core 64-bit processor - 1.86GHz (Nehalem), 4MB Level-3 cache, Intel QuickPath interconnect (QPI) speed 4.8 GT/s, 80 watt thermal design power (TDP), FCLGA 1366 socket
Optional2
Intel Xeon E5504 Quad-Core 64-bit processor - 2.00GHz (Nehalem), 4MB Level-3 cache, Intel QuickPath interconnect (QPI) speed 4.8 GT/s, 80 watt thermal design power (TDP), FCLGA 1366 socket
Intel Xeon E5506 Quad-Core 64-bit processor - 2.13GHz (Nehalem), 4MB Level-3 cache, Intel QuickPath Interconnect (QPI) speed 4.8 GT/s, 80 watt thermal design power (TDP), FCLGA 1366 socket
Intel Xeon E5520 Quad-Core 64-bit processor - 2.26GHz (Nehalem), 8MB Level-3 cache, Intel QuickPath interconnect (QPI) speed 5.86 GT/s, 95 watt thermal design power (TDP), FCLGA 1366 socket
Intel Xeon E5530 Quad-Core 64-bit processor - 2.40GHz (Nehalem), 8MB Level-3 cache, Intel QuickPath interconnect (QPI) speed 5.86 GT/s, 80 watt thermal design power (TDP), FCLGA 1366 socket
Intel Xeon E5540 Quad-Core 64-bit processor - 2.53GHz (Nehalem), 8MB Level-3 cache, Intel QuickPath Interconnect (QPI) speed 5.86 GT/s, 80 watt thermal design power (TDP), FCLGA 1366 socket
7
519737-001
Fan assembly - Includes the fan, blue plastic holder, and cable
8
160GB non-hot-plug SATA hard disk drive - 7,200 RPM, 3.5 inch form factor, 3Gb/sec transfer rate, 3.5 inch Large Form Factor (LFF)
Mandatory1
4-bay SAS/SATA large form-factor (LFF) hot-plug hard drive cage assembly - Does not include the backplane board
Mandatory1
4-bay SAS/SATA hot-plug large form factor (LFF) hard drive backplane board - Mounts on the rear of the 4-bay LFF hard drive cage
10
DVD-ROM optical disk drive - SATA interface, half-height form factor, 16x DVD-ROM read, 40x CD-ROM read
Mandatory1
Battery for real-time clock (RTC) - 3.0V, 220mAh, lithium coin cell, 20mm diameter, 3.2 mm height (CR2032)
Mandatory1
  • Mandatory1 - Parts for which customer self repair is mandatory. If user request HPE to replace these parts, user will be charged for the travel and labor costs of this service.

  • Optional2 - Parts for which customer self repair is optional. These parts are also designed for customer self repair. If, however, user require that HPE replace them for user, there may or may not be additional charges, depending on the type of warranty service designated for product.

Link to product related documents

Click here to view a list of product related documents .

Hp Proliant Ml150 G6 Specs

Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.

Provide feedback

Please rate the information on this page to help us improve our content. Thank you!
  1. Was the information on this page helpful?
Please wait while we process your request.