Ge Security 60-983 Atp1000 Alphanumeric Touchpad User Manual

The GE Interlogix 60-983 ATP1000 is an hardwired alphanumeric alarm keypad that allows you to control your GE Interlogix Concord 4 security system. The 60-983 touchpad is recommended to be used to access the installer programming mode of Concord 4 panels. Jan 03, 2015  utc fire & security 60 983 atp1000 alphanumeric touchpad large 2x16 liquid crystal disp Product information Package Dimensions. Wiring the touchpad to the panel, Attaching the touchpad to the mounting plate, Power up and bus communication – Interlogix ATP1000 User Manual Page 2: Programming Text mode.

Advertising

2. For wall mounting, place the mounting plate on the wall

and mark the mounting holes (see

). Be sure to

leave a 3-inch clearance below for the touchpad door to

open.

Figure 2. Mounting hole locations

Mounting Holes

Mounting Holes

3. Insert anchors into the wall at the marked locations where

studs are not present.

4. Align the mounting plate holes with the wall or gang box

screw holes and secure the back plate using the screws

provided.

Note: Do not over tighten screws or the mounting plate

may bind and prevent the touchpad from mounting

properly.

5. For wall-mount installations, cut a hole in the wall in the

wire access area of the mounting plate to pull the wiring

cable through.

Wiring the Touchpad to the Panel

1. Remove panel AC and backup battery power.

2. Run a 4-conductor, 18- to 22-gauge wire from the panel to

the touchpad location (see

3. Connect the touchpad +12V, BUS A, BUS B, and GND

terminals to the matching panel terminals (see Figure 3 for

touchpad terminal identification)

Figure 3. Touchpad wiring connections

GND

BUS B
BUS A

Ge Security 60-983 Atp1000 Alphanumeric Touchpad User Manual Update

+12V

Attaching the Touchpad to the Mounting Plate

Align the tabs at the top of the mounting plate with the slots on

the touchpad and swing the touchpad bottom toward the

mounting plate. Gently tighten the screw into the bottom of the

touchpad.

Power up and Bus communication

After making all wiring connections from the touchpad to the

panel, you are ready to power up the panel and verify correct

communication between the touchpad and the panel. Upon

power up, the panel scans the bus for connected devices,

assigns a unit number to each bus device, and automatically

learns the device ID number of each bus device.

1. Verify that all wiring between the panel and touchpad is

correct.

2. Connect the panel battery and restore AC power.

Alphanumeric touchpads briefly show SCANNING BUS

DEVICES, then display date and time.

Note: Steps 3 through 9 are optional.

3. At the touchpad, enter program mode by pressing 8 +

installer/dealer code (default = 4321) + 0 + 0. The

touchpad should display SYSTEM PROGRAMMING.

4. Press É and the display shows SECURITY.

5. Press A or B until the display shows ACCESSORY

MODULES, then press É. The display should read BUS

DEVICES.

6. Press É. The display shows the lowest device address

and its ID. The following example shows what a device

address display may look like:

UNIT - ID

0—02110185*

*The 8-digit SuperBus ID number is also located on a label

on back of the touchpad.

7. Press A or B to cycle through all bus device addresses

until the touchpad appears.

User manual for iphone. VersionDescriptionDateCE Doc Revision A1CE DeclarationDEUBandwidthManagementRevABandwidth Management-DEUCiscoFirewallRevADEU Cisco Firewall-DEUDSRSeriesRevADSR-Series-DEUDLinkDFL FirewallRevAD-Link DFL Firewall-DEUFortinetFirewallRevAFortinet Firewall-DEUJuniperFirewallRevAJuniper Firewall-DEUVPNSplittunnelRevAVPN Split tunnel-DEUbalancingRevABalancing-DEUconfigurewpsseriesRevAConfigure wps series-DEUportforwardingRevAPortforwarding-DEUsetupDSRseriesREvASetup DSR-series-DEUsonicwallRevASonicwall-DEUsubnetsDSRSeriesRevASubnets DSR Series.

8. After verifying the touchpad device ID, press Ç repeatedly

until the display shows SYSTEM PROGRAMMING.

9. Press A or B until the display shows EXIT

PROGRAMMING READY, then press É. The touchpad

should show the date and time display.

Programming

To program options for the newly installed touchpad (such as

key beeps) see the specific panel installation instructions.

2

ATP1000 Touchpad/Display Installation Instructions

Advertising
Popular Brands
Popular manuals

Atp1000 touchpad/display installation instructions, Product summary, Installation

Download
Advertising

ATP1000 Touchpad/Display Installation

Instructions

Product summary

The ATP1000 lets you control all programming and operation
of compatible security systems (see the “Specifications”
section).

The large 2-line, 16-character display provides easy to read
messages to indicate the current status of the system. The
touchpad includes police, fire, and auxiliary panic buttons that
can be activated anytime. A built-in speaker provides alarm,
status, and button-press sounds. A swing-down door reveals a
label with basic system operating commands. The door can be
removed by simply opening it past its stop point. The door can
also be reattached later if desired.

Tools and equipment needed

4-conductor, 22- or 18-gauge wire

Screwdriver

#6 screws and anchors (included)

Panhead screws for gang box installation

Saw or utility knife for cutting wallboard

Installation

Installation guidelines

Mount the touchpad in an environmentally controlled area
(32°F to 120°F/0°C to 49°C).

When mounting the touchpad, allow at least 3 inches
below it for the swing-down cover.

Do not exceed the maximum available power. See the
panel installation instructions for maximum available
power.

Table 1

describes the power used by the touchpad.

Table 2

describes the maximum wire lengths allowed

between the touchpad and the panel.

Table 1. Touchpad power usage
Current (mA)

Conditions

110

Maximum alarm current with the buzzer sounding

and the touchpad illuminated from a button press

60

Typical operation

12

Power saving mode (no panel AC power)

Get your Vector-research service manuals fast from ServiceManuals.net. Vector research servic3 manual download. We carry parts and repair service manuals for almost every Vector-research model such as V2000, V2000 BULLETIN - CLICK FOR DETAILS, V2001, V2020 SERVICE MANUAL, V3000, V4000, V4020, V4040. We make it easy for you to quickly repair Vector-research electronic devices with our detailed service manuals. Our Vector-research service manuals are available on CD ROM, downloadable.pdf and as hardcopies that can be directly mailed to you.

Table 2. Maximum touchpad wire lengths
Wire Gauge (Unshielded

or Shielded)

Max. Touchpad Wire Length

Between Touchpad and Panel

18

750 feet

22

300 feet

Installing the Mounting Plate

1. Separate the mounting plate from the touchpad by first

loosening the screw, then lift the touchpad away from the
mounting plate (see

Figure 1

).

Figure 1. Separating touchpad from mounting plate

Loosen screw,

Ge Security 60-983 Atp1000 Alphanumeric Touchpad Manual

then lift touchpad.

P/N 466-2100 • REV I • January 2011

1

Advertising
Table of contents
  • Product summary
    • Tools and equipment needed
  • Installation
    • Installation guidelines
      • Installing the Mounting Plate
  • Connecting the touchpad for system programming only
  • Adjusting display brightness and contrast
  • Changing the touchpad unit number(Concord panels with software version 1.0-1.6 only)